Product Details:
| Throughput | 80 tests/hour |
| Diff Type | 3 Part |
| Parameters | 20 Parameters |
| Sample Type | Pre Diluted, Whole Blood, Capillary |
| Operation Mode | Fully Automatic |
| Printer Type | External Only |
| LIS Connectivity | USB + Ethernet |
| Sample Loading | Open Vial |
| Power Supply | 220–240 V AC |
The Sysmex XQ Series (XQ-320) is a fully automated 3-part differential hematology analyzer designed for laboratories requiring fast, reliable, and low-maintenance CBC testing with premium Japanese technology.
⚙️ Technical Specifications (Strong Points) ✅ Technology👉 More stable and reliable than basic low-cost analyzers
✅ Parameters👉 More detailed than basic 3-part analyzers
✅ Throughput👉 High speed for busy labs
✅ Sample Volume (BIG ADVANTAGE)👉 Lowest in segment – ideal for pediatric & critical patients
✅ Reporting Time👉 Faster patient turnaround
✅ Flagging System👉 Better clinical interpretation support
✅ User Interface👉 Reduces service cost
✅ Connectivity👉 Easy integration in hospital systems
✅ Build Quality| Feature | Sysmex XQ | Competitors |
|---|---|---|
| Sample Volume | 16 µL (Very Low) | 20–50 µL |
| Speed | 70 samples/hr | 50–60 |
| Technology | Advanced | Basic |
| Flagging | 20 smart flags | Limited |
| Maintenance | Weekly only | Frequent |
| Reliability | Premium Japanese | Variable |
| Interface | Touchscreen | Basic display |
👉 “Lowest sample volume (16 µL) in 3-part analyzer – best for pediatric testing”
👉 “Premium Japanese technology ensuring long-term reliability and accurate results”
👉 “Fast reporting within 60 seconds – ideal for emergency labs”
👉 “Low maintenance system – only weekly shutdown required”
Product Details:
| Minimum Order Quantity | 1 Piece |
| Analyzer Type | Hematology |
| Diff Type | 6 Part |
| Model Series | XN Series |
| Parameters | 28 Parameters |
| Throughput | 100–200 tests/hour |
| Application | Reference Lab, Hospital Lab, Clinical Lab |
| Sample Volume | 10 µl |
| Operation Mode | Fully Automatic |
| Sample Type | Whole Blood, Plasma |
| LIS Connectivity | USB, Ethernet, RS-232 |
| Brand Origin | Imported Brand |
The Sysmex XN-L Series is a fully automated 6-part differential hematology analyzer designed for modern laboratories requiring high accuracy, advanced clinical parameters, and superior workflow efficiency.
⚙️ Technical Specifications (Strong Points) ✅ Technology (BIG DIFFERENCE)👉 Competitors usually do NOT provide IG / RET / IPF together
✅ Throughput👉 Ideal for medium to high workload labs
✅ Sample Volume (Very Low)👉 Better than most competitors (less sample, pediatric friendly)
✅ Differential System (TRUE 6-PART)👉 Competitors usually give 5-part or calculated IG
✅ Flagging System (Advanced Diagnosis Support)👉 More accurate clinical decision support
✅ Body Fluid Testing (Unique Advantage)👉 Very few competitors offer this feature
✅ Automation & Workflow👉 Reduces manpower & errors
✅ Data Storage| Feature | Sysmex XN-L | Competitors |
|---|---|---|
| Technology | Laser Flow Cytometry | Mostly Impedance / Basic Optical |
| IG Parameter | ✅ Available | ❌ Not available / Limited |
| RET / IPF | ✅ Advanced | ❌ Rare |
| Body Fluid | ✅ Available | ❌ Not available |
| Accuracy | High (multi-signal analysis) | Moderate |
| Sample Volume | 25 µL | 30–50 µL |
| Flagging | Advanced | Basic |
| Reliability | Premium Japanese | Variable |
👉 “Premium Japanese Technology with Advanced Clinical Parameters (IG, RET, IPF) – Not Available in Standard 5-Part Machines”
👉 “Laser-based hematology analyzer ensuring highest accuracy compared to conventional impedance systems”
👉 “Best choice for labs upgrading from 3-part or basic 5-part analyzers”
Additional Information:
Product Details:
| Automation Grade | Semi Automatic |
| Number Of Channels | 1 |
| Detection Method | Optical |
| Brand | Sysmex |
| Wavelength | 405 nm |
| Memory | 10000 test results |
| Sample Volume | 50 ul |
| Measurement Time | 30 seconds |
| Storage | 1000 samples |
| Type Of Blood Analyzer | Coagulation Analyzer |
The Sysmex CA-101 is a semi-automated blood coagulation analyzer designed for laboratories requiring accurate, reproducible, and easy coagulation testing with minimal manual intervention.
⚙️ Technical Specifications (Strong Points) ✅ Technology (Key Advantage)👉 More reliable than manual visual methods
✅ Test Parameters👉 Covers all routine coagulation tests
✅ Automation Features👉 Reduces manual errors significantly
✅ Accuracy & Reliability👉 Ensures accurate results in difficult samples
✅ Sample & Reagent Efficiency👉 Cost saving for labs
✅ Workflow Advantage| Feature | Sysmex CA-101 | Competitors |
|---|---|---|
| Detection | Optical (objective) | Manual / less precise |
| Accuracy | High | Variable |
| Sample Handling | Automated timing | Manual dependent |
| Sample Type Handling | Lipemic/Icteric support | Limited |
| Ease of Use | Very simple | Moderate |
| Reliability | Premium Japanese | Variable |
👉 “Accurate optical clot detection – no manual interpretation required”
👉 “Reliable results even in lipemic and icteric samples”
👉 “Best semi-automatic coagulation analyzer for routine PT/APTT testing”
👉 “Low reagent consumption – cost-effective solution for labs”
Product Details:
| Minimum Order Quantity | 1 Piece |
| Technology | CLIA |
| Throughput | 150–300 tests/hour |
| Assay Menu | Tumor Marker, Hormone, Cardiac, Fertility, Vitamin D, Thyroid Panel |
| Operation Mode | Random + STAT |
| Sample Type | Serum, Plasma |
| Reagent System | Closed System |
| LIS Connectivity | RS-232 |
| Calibration | On Demand, Automatic, Master Curve |
The DiaSys SYS Aurora is a fully automated Chemiluminescence Immunoassay (CLIA) analyzer designed for laboratories requiring high sensitivity, high specificity, and advanced immunoassay testing.
👉 Ideal for thyroid, tumor marker, fertility, cardiac, and infectious disease testing
⚙️ Technical Specifications (Strong Points) ✅ Technology (BIGGEST ADVANTAGE)👉 Much more sensitive than ELISA methods
✅ Throughput👉 High productivity for busy labs
✅ Test Menu (Very Wide Range)👉 Covers almost all high-value tests
✅ Sample Handling👉 Smooth workflow without interruption
✅ Reagent System👉 Ensures reagent stability
✅ Detection System👉 High sensitivity for low concentration analytes
✅ Magnetic Separation System👉 Improves accuracy and reaction efficiency
✅ Cuvette System👉 No contamination risk
✅ Automation & Software| Feature | DiaSys Aurora | Competitors |
|---|---|---|
| Technology | CLIA (Magnetic + ALP) | ELISA / Basic CLIA |
| Sensitivity | Very High | Moderate |
| Throughput | 180 T/H | 100–150 |
| Automation | Fully automatic | Semi / limited |
| Magnetic Separation | 4-phase system | Basic |
| Detection | PMT (high precision) | Standard |
| Test Menu | Wide | Limited |
👉 “High sensitivity CLIA technology – superior to ELISA-based systems”
👉 “Advanced magnetic particle system ensures highest accuracy”
👉 “Complete immunoassay solution – thyroid, tumor, fertility, cardiac & more”
👉 “High throughput 180 tests/hour – ideal for growing labs”
💰 Business Advantage (VERY IMPORTANT FOR YOU)👉 This machine gives:
Product Details:
| Parameters | Na+K+Cl |
| Technology | ISE |
| Throughput | 60 tests/hour |
| Sample Type | Whole Blood, Urine, Serum, Plasma |
| Sample Volume | 60 µl |
| Calibration | Automatic |
| Reagent Type | Pack |
| Operation Mode | Fully Automatic |
| LIS Connectivity | Ethernet, RS-232, USB |
👉 Multiple model options available (Na/K, Na/K/Cl, etc.)
🔹 Veterinary Mode👉 Useful for veterinary labs and research applications
🔹 Sample Capacity👉 “Fast electrolyte results in less than 60 seconds using ISE technology”
👉 “Low maintenance system with disposable solution pack”
👉 “Accurate sodium, potassium, chloride testing for ICU & emergency labs”
👉 “Available in multiple models as per lab requirement”
Product Details:
| Minimum Order Quantity | 1 Piece |
| Throughput | 400 tests/hour |
| Parameters | More than 200 |
| Sample Capacity | 40 samples |
| Reagent Positions | 40 positions |
| Sample Type | Urine, Plasma, Whole Blood, Serum, CSF |
| Reagent Cooling | Yes |
| Wavelength Range | 340–800 nm |
| User Interface | Touchscreen + PC |
| Connectivity | RS232, USB, Ethernet, LIS Support |
| Country Of Origin | Germany |
👉 Includes:
👉 “Compact fully automated analyzer with 200 tests/hour throughput – ideal for small to mid-size labs”
👉 “Supports 100+ parameters with open reagent system”
Additional Information:
Product Details:
| Minimum Order Quantity | 1 Piece |
| Throughput | 600 tests/hour |
| Parameters | More than 200 |
| Sample Capacity | 120 samples |
| Reagent Positions | 60 positions |
| Sample Type | Whole Blood, Urine, Plasma, Serum, CSF |
| Reagent Cooling | Yes |
| Wavelength Range | 340–800 nm |
| User Interface | Touchscreen + PC |
| Connectivity | LIS Support, Ethernet, RS232, USB |
| Country Of Origin | Germany |
| Feature | SYS 680 Ci | Competitors |
|---|---|---|
| Throughput | 600 T/H | 400–560 |
| Sample Handling | Continuous + STAT | Limited |
| Automation | Fully advanced | Moderate |
| Test Menu | Very wide | Limited |
| Efficiency | High | Moderate |
👉 “Advanced automation with continuous loading and STAT priority”
👉 “Supports wide range of routine and specialized tests”
👉 “Perfect solution for medical colleges and large hospitals”
💰 Business Advantage (Very Important)👉 This machine gives:
Additional Information:
Product Details:
| Minimum Order Quantity | 1 Piece |
| Throughput | 400 tests/hour |
| Parameters | More than 200 |
| Sample Capacity | 50 |
| Reagent Positions | 50 positions |
| Sample Type | Whole Blood, Serum, CSF, Plasma, Urine |
| Reagent Cooling | Yes |
| Wavelength Range | 340–800 nm |
| User Interface | Touchscreen + PC |
| Connectivity | USB, LIS Support, RS232, Ethernet |
| Country Of Origin | Germany |
The DiaSys SYS 240 Pro is a fully automated clinical chemistry analyzer designed for laboratories requiring high accuracy, flexibility, and efficient workflow in routine and special biochemistry testing.
👉 Ideal for hospitals, diagnostic labs, and medical colleges
⚙️ Technical Specifications (Strong Points) ✅ Technology👉 Supports wide range of biochemical tests
✅ Throughput (KEY SELLING POINT)👉 Perfect for medium to high workload labs
✅ Sample Handling👉 Improves lab efficiency
✅ Sample Volume (High Precision)👉 Low reagent consumption + high accuracy
✅ Reagent System👉 Maintains reagent stability
✅ Reaction System👉 Ensures consistent results
✅ Optical System👉 Better accuracy than basic analyzers
✅ Quality Control👉 Meets NABL & hospital standards
✅ Probe System (Advanced Safety)👉 Prevents errors and damage
✅ Washing System👉 Ensures contamination-free results
✅ Connectivity👉 Low operating cost
✅ Build & Design| Feature | SYS 240 Pro | Competitors (Erba / Transasia / Mindray) |
|---|---|---|
| Throughput | 240–400 T/H | 200–300 |
| Wavelengths | 12 | 8–10 |
| Sample Volume | 2 µL (Very Low) | 3–10 µL |
| QC System | Advanced (Westgard) | Basic |
| Probe Safety | LLD + Clot Detection | Limited |
| Washing | Multi-step (Low carryover) | Moderate |
| Flexibility | High | Moderate |
👉 “High throughput 240–400 tests/hour – ideal for growing labs”
👉 “Advanced QC system (Westgard rules) ensuring NABL compliance”
👉 “Low sample consumption (starting from 2 µL) reduces reagent cost”
👉 “Optional ISE integration – complete biochemistry + electrolyte solution”
Additional Information: